Honeywell ST 800 series pressure transmitter STD810- E1ACAAS -1-0- DHS -11SA -1 supports SIL 2/3

Honeywell ST 800 series pressure transmitter STD810- E1ACAAS -1-0- DHS -11SA -1 supports SIL 2/3

ブランド名: Honeywell
モデル番号: STD810- E1ACAAS -1-0- DHS -11SA -1
MOQ: 1
価格: Negotiations
詳細情報
起源の場所:
アメリカ合衆国
電源:
最大11~42ボルトDC
作動圧力を許容する:
350kPaダイヤフラム
SS充填液:
DC200
加工温度:
-40〜125°C
範囲:
-2.5~2.5kPa
パッケージの詳細:
新しいオリジナルボックス
ハイライト:

Honeywell ST 800 pressure transmitter

,

SIL 2/3 compliant pressure transmitter

,

STD810 pressure transmitter with warranty

製品説明
Honeywell ST 800 Series Pressure Transmitter STD810-E1ACAAS-1-0-DHS-11SA-1 Supports SIL 2/3
Honeywell ST 800 series pressure transmitter STD810- E1ACAAS -1-0- DHS -11SA -1 supports SIL 2/3 0
Product Overview

The Honeywell ST 800 series pressure transmitter STD810-E1ACAAS-1-0-DHS-11SA-1 is a high-performance differential pressure transmitter that supports SIL 2/3.

Key Features
  • Part of the SmartLine® family of products using piezoresistive sensor technology
  • Combines differential pressure sensing with on-chip static pressure and temperature compensation
  • High accuracy and stability over wide range of application pressures and temperatures
  • Accuracy up to 0.035% of span as standard (optional 0.025% of span)
  • Stability of up to 0.01% of URL per year for 15 years
  • Automatic static pressure and temperature compensation function
  • Rangeability up to 400:1
  • Fast response time (as fast as 90ms)
  • Multiple local display capabilities
  • External zero, span, and configuration capabilities
  • Polarity-insensitive electrical connections
  • Comprehensive on-board diagnostic capabilities
  • Integral dual-seal design for highest safety (ANSI/NFPA 70-202 and ANSI/ISA 12.27.0 compliant)
  • World-class overpressure protection
  • Fully compliant with SIL 2/3 requirements
  • Modular design with optional 15-year warranty
  • Options include plugged impulse line detection and dual/triple calibration (for HART & Fieldbus only)